it | en
Battery Charger three-phase
ng9 can bus > Battery Charger three-phase

ng9 can bus - Battery Charger three-phase

Product topic


POWER IS COMMUNICATION • The new three-phase battery charger with CAN BUS interface represents the innovation in Zivan’s range. Thanks to a “flash” microprocessor endowing with high calculation power and huge storage capacity it is able to view in historical perspective the main data concerning last recharging cycles, elevating its feasibility and performance. By a sole button it is easy to modify the charging features, visualize them on the display and fit them to any type of battery. The high power and efficiency of these Zivan’s chargers guarantee a significant energy saving and subsequent economic advantage. This allows to amortize within short times the investment on choosing high frequency, ranking these chargers among the leader items available on the market with the best relationship between quality and price.

    THREE-PHASE BATTERY CHARGER Mod. NG5 / 7 / 9 CAN BUS
  • Input voltage: 400 VAC ± 15% Three Phase
  • Input frequency: 50 – 60 Hz
  • Efficiency: up to 93%
  • Minimum power absorbed: < 10 W
  • Current absorbed by the battery: < 0,5 mA
  • Operating temperature: from – 20 to + 50 °C
  • Output short-circuit protection (fuse)
  • Inverse polarity protection (fuse)
  • Charging Curve: programmable
  • Visualization by display of the parameters: Voltage, Current, charged Ah and time left to the end of charge
  • Accuracy on output voltage: ± 0,5 %
  • Thermal compensation of battery voltage (optional with thermal sensor)
  • Dynamic compensation of the voltage drop on the output cable
  • Acoustic alarm
  • Auxiliary contacts of main presence and end of charge (Standard Charger) or of air pump control and end of charge (Charger with air pump)
  • Cooling: forced
  • Case: Metal base, cover in self-extinguishable ABS
  • Size: 545 x 265 x 115 mm
  • Weight: 9 kg
  • Enclosure class: IP20
  • In conformity with the requirements of the Low Voltage Directive and of the Directive EMC
V 7+8,5 h 9+11 h 12+13 h Tipo VAC I1 IMAX rete
80 385-575 640-770 830-895 80V 100A 400 80 96 18
72 430-650 720-865 935-1010 72V 110A 400 90 108 18
48 575-865 960-1150 1250-1345 48V 145A 400 120 144 16
36 575-865 960-1150 1250-1345 36V 145A 400 120 144 12
24 575-865 960-1150 1250-1345 24V 145A 400 120 144 8

Exemples de courbes de charge

peso: 9 kg weight

cod. Z-C14587
ROLL BAR

cod. P04509
STAND
A support to place the Charger on the ground.

cod. P14011 – 200 cm
THERMAL SENSOR
compensates the recharging parameters depending on the battery temperature.